speedwave ENTRY

The Efficient.

  • Lowest operating costs - guaranteed
  • Simple, intuitive operation
  • Active cooling with fan system
  Open brochure   

The ideal microwave digestion system for routine environmental, food and pharmaceutical analysis. Cost-efficient - Safe - User-friendly

Berghof microwave speedwave ENTRY

Advantages

Lowest operating costs - guaranteed

Thanks to the unsurpassed durability of the vessels, they are included in the warranty of the basic unit. The warranty can be extended to 5 years.

Simple, intuitive operation

Vessels are easy to open, close and clean manually. Sensors do not need to be connected and the software is intuitive to use.

Active cooling with fan system

Active cooling enables high sample throughput and avoids corrosion.

Technology

Berghof microwave digestion speedwave ENTRY
Product Description

The speedwave ENTRY shows its strengths in application areas where cost efficiency is a key issue. It is therefore used in routine analysis in environmental, food and pharmaceutical applications. Easy to operate, yet cost-efficient and safe.

Berghof microwave digestion speedwave ENTRY
Sensor Technology
speedwave ENTRY sensor technology

The speedwave ENTRY also features the patented optical measurement technology speedwave® DIRC, which allows direct and contactless real-time recording of the sample temperature.

In contrast to other methods, the sample temperature is measured with the speedwave ENTRY in all vessels, not just in a reference vessel. The maximum sample temperature is displayed.

Intuitive Operation
speedwave XPERT intuitive operation

Starting the speedwave ENTRY is quick and easy.

  • Easy opening and closing of vessels without tools

  • Pre-programmed applications for routine analytics

  • Start of digestion in just two steps

External exhaust unit
speedwave XPERT safety

The additional suction unit permanently ventilates the furnace chamber and ensures that the specimens cool down more quickly. Highest sample throughputs are thus possible.

TFMTM-PTFE-Vessels
Speedwave XPERT PTFE vessels

Vessels from Berghof significantly reduce the running costs for microwave digestions. Due to high-quality processing and outstanding lifetime, the cost per digestion for Berghof vessels is € 0.30 only.

In comparison: Vessels from other vendors generate average costs of € 1.00 per digestion. This means that the running costs can be reduced by approx. € 7,000 for 10,000 digestion cycles

Corrosion protection reduces repair costs

In operation, all vessels are connected to a gas collection system, which collects any acid vapors released and and feeds it to the exhaust air. This effectively prevents acid vapors from entering the furnace chamber and thus corrosion of various sensors, components, or parts caused.

Technical specifications

 

DAP-60K DAP60K

DAQ-10 DAQ10

Volume 60 ml 10 ml
Working pressure 40 bar 75 bar
Operating temperature 230° C 230° C
Rotor 10 vessels 24 vessels
 

speedCAP

Type of vessel TS-85
Power supply 230 V, 50/60 Hz
Speed range 45 - 90 rpm
Weight ca. 4,5 kg
Dimensions 230 x 277 x 152 mm (W x D x H)
With our Product Comparison you can easily compare this product with others.
Compare products

Application areas and applications

  • Food & feed

    • Digestion of beverages, animal products, milk products, fruit, coffee, beer, cereals, nutrients and coconut oil
  • Pharma & cosmetics

    • Digestion of blood, hair & bone
  • Environment & geology

    • Digestion of filter/emissions, sediments, soil, sludge, waste water/water, wood
  • Technology

    • Digestion of PET, polyester, bronze
Application

Microwave Digestion of bread (without pressure monitoring)

Digestion of bread using the speedwave ENTRY.

 See application
Application

Microwave Digestion of PET (without pressure monitoring)

Digestion of PET using the speedwave ENTRY.

 See application
Application

Microwave Digestion of Emissions according to DIN EN 14385 (without pressure monitoring)

Emissions are digested in accordance with DIN EN 14385 using the speedwave ENTRY.

 See application
Application

Microwave Digestion of Particulate Matter (PM10) according to DIN EN 14902 (without pressure monitoring)

The Berghof speedwave ENTRY allows microwave digestion of particulate matter (PM10) in accordance with DIN EN 14902.

 See application
Application

Microwave Digestion of wastewater according to EPA 3015A for speedwave ENTRY

Wastewater samples are digested in an acid solution using the Berghof speedwave ENTRY.

 See application

Accessories

Accessories

speedwave Microwave Digestion Accessories For optimized processes in the lab

Useful accessories facilitate everday's lab work.

 See accessory
Accessories

distillacid BSB-939-IR accessories For gentle acid distillation with a high purification level

The cost-efficient alternative to achieve highly purified acids.

 See accessory
Accessories

speedwave ENTRY External Exhaust Unit For more safety and fast cooling

For vacuuming exhaust air out of the oven chamber.

 See accessory
MENU
Inquiry